Proper study guides for Far out IBM IBM Cognos TM1 10.1 Administrator certified begins with IBM C2021-703 preparation products which designed to deliver the High value C2021-703 questions by making you pass the C2021-703 test at your first time. Try the free C2021-703 demo right now.
♥♥ 2021 NEW RECOMMEND ♥♥
Free VCE & PDF File for IBM C2021-703 Real Exam (Full Version!)
★ Pass on Your First TRY ★ 100% Money Back Guarantee ★ Realistic Practice Exam Questions
Free Instant Download NEW C2021-703 Exam Dumps (PDF & VCE):
Available on:
http://www.surepassexam.com/C2021-703-exam-dumps.html
Q21. You want to deploy a new application using dimension calculations in Performance Modeler. The application will be deployed in distributed mode.
Which two configuration parameters should be applied? (Choose two.)
A. PersistentFeeders=T
B. AllowSeparateNandCRules=T
C. DistributedPlanningOutputDir=.\tunit
D. LoggingDirectory=. . \log
Answer: B,C
Q22. Which two log files would you review to determine if a TM1 Server has successfully registered with the Admin Server? (Choose two.)
A. TM1 Admin Server log
B. TM1 Transactions log
C. TM1 Server log
D. TM1 Audit log
Answer: A,C
Q23. You want to create documentation which is stored on the TM1 Server. You need to create a cube in which you can hold user entered text comments on all processes on the TM1 Server.
Which two dimensions would you use? (Choose two.)
A. The \}Processes control dimension
B. A dimension with a string item
C. \}ConnectionProperties control dimension
D. The \}PerfCubes control dimension
Answer: A,B
Q24. When configuring IBM Cognos TM1 applications, which IntegratedSecurityMode parameter settings are permitted?
A. Only mode 1
B. Modes 1 or 5
C. Modes 4 or 5
D. Only mode 5
Answer: B
Q25. A user is only allowed to enter data into cubes for the East region. The user should not be able to see entries for the West, North, and South regions.
To provide this level of access, which security should be set?
A. Set access to "None" for dimension elements West. North, and South and "Read" for East.
B. Set access to "Read" for dimension elements West, North and South and "Write" for East.
C. Set access to "None" for dimension elements West, North and South and 'Write" for East.
D. Set access to "None" for dimension elements West, North and South and "Read" for East.
Answer: C
Q26. A company has TM1 production servers scattered across the globe. The North American server contains the base data that is used by all servers globally. The source data for the North American TM1 Server resides locally and is updated using an ODBC connection.
What is the optimal TM1 method for keeping the base data in the global TM1 servers consistent with the base data in the North American TM1 Server?
A. Send copies of the TM1 log files from the North American server to the administrator of each global TM1 server and have them process it against their local TM1 Server.
B. Have a compressed copy of the North American production TM1 Server's data directory sent to the other global locations using FTP and restore this data onto each local TM1 Server.
C. Set up an ODBC connection to the North American production source data on each of the TM1 servers across the globe and run TurboIntegrator processes to update the global TM1 servers.
D. Set up a replication and synchronization nightly chore between the TM1 servers across the globe and the TM1 Server in North America.
Answer: D
Q27. What happens when PerformanceMonitorOn is set to true (T) in the tm1 s.cfg file?
A. User access is restricted to the TM1 Server while server diagnostics occur.
B. TM1 performance monitoring records performance statistics for clients, cubes, and the TM1 Server.
C. Advanced error logging occurs when running TurboIntegrator processes.
D. Feeder optimization is traced and logged into a system control cube.
Answer: B
Q28. Which two statements are true regarding TM1 Bulk Load Mode? (Choose two.)
A. No new user connections are allowed after Bulk Load Mode is initiated.
B. Bulk Load Mode can be initiated through TM1 Rules.
C. Bulk Load Mode can be initiated through the TM1 Operations Console.
D. Bulk Load Mode can be initiated through TM1 TurboIntegrator.
Answer: A,D
Q29. Click the Exhibit button.
Two security groups exist with the permissions shown in the exhibit.
If a TM1 user is assigned to both groups, which permissions will be granted for the elements: England, France, Germany and Korea?
A. England (Read), France (Read).Germany (Write) and Korea (Read)
B. England (Read), France (Write).Germany (Write) and Korea (Read)
C. England (Write), France (Read).Germany (Read) and Korea (Read)
D. England (Write), France (Read).Germany (Write) and Korea (Read)
Answer: D
Q30. Which statement about Data Reservations in TM1 is true?
A. Granting a Data Reservation always permits users to write to the cube data, regardless of their security rights.
B. If the REQUIRED Data Reservation mode is set for a cube, users must take a Data Reservation to write data to the cube.
C. A user can secure a Data Reservation from the Security menu for the cube in Server Explorer.
D. Data Reservations are granted to groups and applies to all users in that group.
Answer: B