Exam Code: C2090-304 (Practice Exam Latest Test Questions VCE PDF)
Exam Name: IBM InfoSphere QualityStage v9.1 Solution Developer
Certification Provider: IBM
Free Today! Guaranteed Training- Pass C2090-304 Exam.
2021 May C2090-304 Study Guide Questions:
Q11. You created a job that uses the standardization stage with a new copy of USADDR rule set. The job was successfully compiled, but has an error and will not run.
What is most likely the cause of the problem?
A. The input file is missing.
B. The rule set is not provisioned.
C. The server does not have enough memory.
D. The rule set has an invalid statement in the pattern file.
Answer: C
Q12. In order to accomplish Word Investigation in a single QualityStage job, how many investigate stages would be required for the following fields:
PREFIX, FIRST_NAME, LAST_NAME. SUFFIX. ADDRESSJI. ADDRESS_2, ADDRESS_3, CITY, STATE. andZIPCODE?
A. Ten.
B. Five.
C. Three.
D. Seven.
Answer: A
Q13. What would happen if a special character is included in the SEPLIST and not in the STRIPLIST?
A. That special character will be ignored.
B. You will get an error when you test a statement.
C. The token class for that character becomes the character itself.
D. You need to enclose in double quotes any special characters in the SEPLIST that is not in the STRIPLIST.
Answer: C

Rebirth C2090-304 actual exam:
Q14. A match review was just completed and determined that individuals with different middle names are being grouped together.
Which option would be effective in breaking these two individuals apart?
A. Decrease the value of the m-prob for the middle name
B. Set the override file A missing weight for middle name.
C. Set the override disagreement weight for middle name.
D. Set the override disagreement weight for primary name.
Answer: C
Q15. In the output fields available from the Name Standardize rule set, how many MatchPrimaryWords are defined?
A. Two
B. Three
C. Four
D. Five
Answer: A
Q16. Which statement is true?
A. Complex Boolean survivorship rules are permitted.
B. The first defined survivorship rule takes precedence.
C. Complex fuzzy matching survivorship rules are permitted.
D. Blank fields are automatically dropped from survivorship consideration.
Answer: B

Guaranteed C2090-304 preparation labs:
Q17. In addition to the QualityStage module, what product do you need to deploy a QualityStage job as a service?
A. DataStage
B. Federation Server
C. Tivoli Deployment Manager
D. Information Services Director
Answer: B
Q18. Which statement is true regarding QualityStage data survivorship?
A. Survivorship is used to create groups of duplicate records.
B. The Survive stage is used to mark records as possible duplicates.
C. The Survive stage is used after matched record groups have been identified.
D. The Survive stage can be used to correct and identify unhandled data from the Standardize stage.
Answer: C
Q19. How can Word Investigation reports be used to modify a rule set?
A. Corrects spelling errors in the data field.
B. Adds tokens to allow identification of additional duplicates.
C. Identifies new tokens to allow additional words to be classified.
D. Identifies matched words to be used in match designer frequency distribution.
Answer: A
Q20. You added a new field to matching fields of an existing match specification and provisioned all match specification components. Then you ran the job but it failed immediately. The input data size is 2G bytes and the job worked without any issues before you modified.
What is most likely the cause of the problem?
A. Lack of physical memory.
B. Lack of scratch disk space.
C. The job needs to be re-compiled.
D. The frequency file needs to be re-generated.
Answer: A